บริษัท เอกเสคคิวทิฟ เทรดดิ้ง จำกัด
EXECUTIVE TRADING LIMITED

 


Most sold olfactometer worldwide

The popularity of the TO8 is indisputable: it is the most sold olfactometer worldwide. It meets all requirements of a dilution device for olfactometric measurements according to EN 13725. It uses a unique and specially designed dilution system for odour samples.

The TO8’s main application is to measure odour concentration, providing a full record of  the data obtained, according to EN 13725. The measurement process is fully automated. It can also be used to assess hedonic tone or intensity (VDI 3882).

The compact size and transportability of this model means you can measure onsite in a mobile laboratory if required – and so keep sample storage time to a minimum.

FACTS:

  • Most sold olfactometer worldwide
  • Fully automatic, 100 % compliant to EN 13725
  • Unique + special designed dilution system
  • Software includes project + panel database
  • Yes-/No-Method, Intensity + Hedonic Tone
  • Fastest analysing time, Fastest setup time
  • Mobile & plug and play technology
  • Heated dilution system to prevent contamination 
SCOPE OF SUPPLY:
  • Filter system
  • Robust transport box
  • Heating system to prevent contamination
  • Full version software: Dynamic olfactometry and intensity/ hedonic tone on USB stick
  • 5 m compressed air connecting PTFE pipeline
  • Compressed air connection (8mm external)
  • 50 x 10 l bags
  • Proprietary calibration certificate in accordance with ISO 17025 

Manufacturer

Dimension (L x W x H)

a) assembled

b) transport size

Weight

Maximum calibration interval

Warranty


Olfasense GmbH, Germany

 

a) 650 x 650 x 470 mm

b) 650 x 650 x 270 mm

17 kg

12 months (according to EN 13725)

24 months (warranty extension up to 5 years through servicecontracts possible

Dilution principle

Vent for surplus diluted odour

Number of panel members working  simultaneously

Maximum panel size (software setting)

Analyses time for one sample (EN13725:2003)

Required air supply

Dilution range

Interval steps

Dilution accuracy

Response / setting time

Required sample volume


Gas jet pumps and calibrated precsion orifices for sample dosage

Outlet air via active carbon filter

4

16

5 min

115 l/min, oil-free

22 (1:4) - 216 (1:65,536)

Factor 2

< 5%

< 0.1 sec

High concentrations: 1-2 liter

Low concentrations: 6-8 liter

Contact Us
EXECUTIVE  TRADING LIMITED .,THAILAND
48/194-5 SOI,PRADIT MANUTHAM19,PRADIT MANUTHAM RD. 
LATPHRAO BANGKOK 10230, THAILAND
TEL.+662 515 0145-50, FAX.+662 515 0144

  
Google Map
  2020 Executive Trading Limited